Project Description

A new meter GAMA 300 has been developed for the very rapidly changing electricity market, adapted to deregulation and customers’ growing demands. The electronic electricity meter GAMA 300 operates in three-phase electricity networks and is approved in accordance with IEC 62052-11, IEC 62053-21, IEC 62053-22, IEC 62053-23, EN 50470-1 and EN 50470-3. The electricity meter satisfies the requirements of Directive 2004/22/EC of the European Parliament and of the Council of 31 March 2004 on measuring instruments.

Additionally meter can be equipped with communication modules upon request, allowing easy connection of meters to AMR system directly. The GAMA 300 meter has a changeable (without uninstalling meter from site) Li-ion battery and an internal relay for remote user disconnection.

Features :

  • Measuring
  • Tariff module
  • Data storage
  • Billing
  • Load Profiles
  • Communications
  • Outputs / Inputs
  • Security features
  • Power Quality Monitoring (Optional)
  • Display

Main Technical Parameter

Ratings
System Three-phase 4-wire or 3-wire
Accuracy class:
• For active energy
• For active energy, CT only
• For reactive energy
Class 
• class 1.0 (IEC 62053-21), class B (EN 50470-3)
• class 0.5s (IEC 62053-22), class C (EN50470-3)
• class 2.0 (IEC 62053-23)
Reference voltage, V:
• 4-wire networks
• Multirange
• 3-wire networks
V
• 3×220/380; 3×230/400; 3×240/415; 3×57,7/100; 3×63,5/110; 3×69,2/120; 3×120/208; 3×127/220
• 3×57,7/100…230/400
• 3×100; 3×110; 3×120; 3×220; 3×230
Reference (maximum) current, A:
• Directly connected
• CT operated
A
• 5(60); 5(80); 5(100); 5(120); 10(60); 10(80); 10(100);
• 1(1.25); 1(6); 5(6.25); 5(10);
Current threshold 0.4% I (0.1% I if CT operated)
Reference Frequency, f 50 or 60 Hz
Meter constant, imp/kWh, imp/kVArh 1…19999 (direct), 1…60000 (CT operated)
Power consumption per phase:
• In voltage circuit
• In current circuit
Power
• < 0.5W < 1.0 VA
• < 0.05 VA (< 0.5 VA if CT operated)
Temperature ranges:
• Meter operating
• Meter storage
Temperature
• -40°C…+70°C
• -40°C…+70°C
Internal real-time clock
Accuracy < 0.5 s/24h (T = 23°C)
Backup power supply Li-ion battery and/or Super-Cap
Li-ion battery Changeable on operating meter
Operation duration using only backup:
• Li-ion battery
• Super-Cap
Backup
• > 10 years
• up to 7 days
Case & Dimensions
Case UV stabilized polycarbonate
Insulation Protective class II
Protection Class IP51
Dimensions, mm 260 x 175 x 80

Project Details

Client:Oak Hotel
Location:Barcelona, Spain
Value:$6,000
Share